Technical parameters of GKC-HB high voltage switch comprehen
Release time:2021-04-22
Read:87
1. Time measurement:
12 channels inherent opening (closing) time
Different periods in the opening (closing) phase
Different periods of opening (closing)
Closing (opening) bounce time (bounce times)
Test range: 0.01ms~20s, resolution: 0.01ms
Test range: 20s~200s, resolution: 0.1ms
Accuracy rate within 200ms: (0.1%t±0.1)ms
2. Measurement of closing resistance:
6 inherent opening (closing) time
Different periods in the opening (closing) phase
Different periods of opening (closing)
Closing resistance input time
3. Measuring range: 10~10KΩ, resolution 0.1Ω, accuracy: 5%±1 word
4. Speed measurement: just opening (just closing) speed
Average speed in a specified time period (stroke period or angle period)
5. Speed measurement range: 1mm sensor 0.01~25.00m/s,
0.1mm sensor 0.001~2.50m/s
0.5° angle sensor 1 cycle / 0.5°
6. Stroke measurement: moving contact stroke (stroke)
Contact stroke (open distance)
Overshoot stroke or reverse stroke (overtravel)
Linear sensor: 50mm, resolution: 0.1mm, measuring range: 0-50mm.
360 line sensor: 360о, resolution: 0.5о, measuring range: 0-1000mm.
7. Current: The maximum current output is 20A (optional 30A) and the minimum resolution: 0.01A.
8. Instrument power supply: AC/DC 220V ± 10%; 50Hz ± 2%
9. Internal DC power supply: output DC15~265V continuously adjustable, output current: ≤ 20A (short time)
10. Isolation switch measurement range:
⑴. Voltage output: DC15~265V (adjustable);
⑵ Power output time: 0.01-20 seconds (can be set);
⑶, the maximum collection time of fracture signal is 200 seconds;
⑷, measurable fracture closing time, opening time, three-phase different period, bounce time and frequency
11. Host volume: 380×280×170mm
12. Use environment: -20℃~+50℃
13. Relative humidity: ≤90%
THE LAST
THE NEXT
RELATED ARTICLES
Which transformer tester is better? "Exclusive Answer"
2021-05-31
Introduction of Transformer Comprehensive Tester "Experienc
2021-05-31
Wiring method of relay protection tester "Detailed explanat
2021-05-24
LEARN MORE
E-MAIL TO :
daixianpeng153@Outlook.com
About
Company Profile
Company History
Enterprise Qualification
Products
All
Transformer Tester
Relay Protection Tester
News&Events
Company News
Support
+86-13037140838
daixianpeng153@Outlook.com
303 Optics Valley Avenue, Donghu Development Zone, Wuhan City
Copyright © wuhanlongdian All rights reserved
+86 15391500021
daixianpeng153@Outlook.com
daixianpeng153@Outlook.com
+86-13037140838