Transformer capacity tester
Transformer capacity tester
Transformer capacity tester
LDRL-506A

Transformer capacity tester

Note: Users who purchase this product can enjoy free technical guidance, one-year warranty, and lifetime maintenance services
Introduction parameter characteristic atlas Service Recommended

Introduction

Transformer capacity tester is specialized in bad power users evading basic electricity fee and secretly ;adding capacity problems and is a new-type high precision instrument specially used for the measurement of the transformer capacity and characteristic parameters. This product use wide-screen color LCD , English display, simple and quick menu operation, human-machine interface is very friendly. There is a built -in rechargeable battery inside the instrument and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets of transformer. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the voltage regulator, current regulator and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of your work.

This is a multi-functional measuring instrument, which is equivalent to two common meters: such as active transformer capacity tester plus transformer parameter tester. It can be used for test transformer capacity, type, no-load current, no-load loss, load loss, impedance voltage and so on.

This product has many advantages such as small dimension, light , high accuracy, good stability, simple operation and so on. It can replace of the commonly many meters, you can measure the transformer loss and capacity with simple wiring and convenient testing in only one this kind of instrument so that the work efficiency can be greatly improved.

parameter

The output range of built-in batteryVoltage:0~10V
Current:0~10A
The input range of characteristic test power sourceVoltage:0~750V
Current:0~100A
Accurate of testVoltage, current:±0.2%
Power:±0.5%(CosΦ>0.1), ±1.0%(0.02<CosΦ<0.1)
The requirement of chargerElectric supply AC160V~265V
Adapter output 12.6V 1000mA
tip:

1. The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice. 2. To learn more about Longdian products, please enter the product center. Service Hotline: 400-6727-238

characteristic

We can measure a variety of distribution transformer, power transformer capacity instead of the additional extra power. It is more convenient and efficient.

Combined with the external power source, voltage, current regulator equipment etc, it can measures various transformer parameter such as no-load current, no-load loss, impedance voltage, load loss and so on.

Characteristic test of transformer, test range is wide,flexible configured.only through the simple connection to current transformer and voltage transformer, test scope can be enlarged to high-grade power transformer.

Short-circuit the terminals of cable,humanization design,with lock,easy connected to fasten units of transformation.

All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients etc), then the instrument can automatically calibrate such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction,so that the accurate is much higher

The maximum voltage is up to 750V and the maximum current is up to 100A range with protection circuit in it,when you make the characteristic test of transformer.don’t worry the precision and damage of the instrument due to in-proper shift.

The voltage and current range can be very flexible and easy to expand by connecting the external CT or VT

It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature tolerance, brightness adjustable type LCD screen, which can adapt to the different temperature.

Thermal sensitive printer is set inside the instrument,it can easily print on site.

atlas

Service

2h Telephone response
8h Provide solutions
48h Technicians arrive